RCTC Computerized General Refrigeration Trainer Refrigeration Training Equipment Technical Training Equipment
This trainer is designed for the in-depth study of vapourcompression cycle; it uses a personal computer (supplied on demand), data acquisition and PC interface board, suitable transducers and sensors.
TRAINING PROGRAM
• Plant starting and safety devices intervention checking
• Analyzing the system behaviour versus the variation of:
- expansion device
- valve opening degree (when the electronic valve is used for expansion)
- air flow rate at condenser and/or evaporator
• Plotting the cycle in the refrigerant pressure-enthalpy diagram
• Data acquisition and calculation of:
- heat balances corresponding to evaporator, condenser, compressor
- refrigerant mass flow
- ideal and actual EER
- volumetric compression efficiency
• The software of the equipment allows to enter different sections:
- system automatic and manual operation
- refrigerating circuit heat balance
- faults enabling (10)
- troubleshooting and plant operation reset
- system supervision with display of the values detected by the sensors
TECHNICAL SPECIFICATIONS
• Steel structure mounted on wheels, painted and treated in the oven
• Colour silk-screen-printed schematic diagram of the hydraulic circuit with warning LEDs
• Hermetic compressor
• Forced-air condenser with variable flow settable by potentiometer, equipped with 8 glass pipes for displaying the refrigerant condensation process
• Forced-air evaporator with variable flow settable by potentiometer, equipped with 8 glass pipes for displaying the refrigerant evaporation process
• Devices for liquid lamination: electronic expansion valve, capillary tubes of different length
• Liquid receiver, liquid separator
• Solenoid valves, on-off valves, sight glass, dehydrator filter
• Valve for plant vacuum, refrigerant charging and recovering
• Pipes connecting the various components painted with different colours
• Transducers and sensors for detecting the following system operating parameters: voltage, current, power factor, temperatures, cycle pressures, refrigerant flow rate
• High and low pressure gauges
• High and low pressure switches
• Thermomagnetic - earth leakage control button
• Emergency button
• PC control program
Power supply: 230 Vac 50 Hz single-phase - 600 VA (Other voltage and frequency on request)
Dimensions: 140 x 80 x 180 cm
Net weight: 145 kg
Supply with