PLC-V8 PLC Training Panel Vocational Training Equipment PLC Training Equipment
Inside a laboratory for automation technologies, the trainer mod. PLC-V8 is the necessary tool for the high level training of technicians operating in modern process industry, for installations maintenance and program designing levels. TRAINING PROGRAM: The trainer PLC-V8 enables the theoretical analysis and theexperiments on the following main exercises: • PLC architecture • Instructions processing: the cycle concept • Synchronous, asynchronous and priority cycles • 2 rotating potentiometers for setting the analog references • Ø 4 mm and Ø 2 mm standard safety terminals for theconnection of I/O to external devices • Communication Protocol: TCP/IP • Industrial communication interface: ProfiNet • Performing times, cycle and reaction • Boolean Algebra • KOP and FUP basic programming • Combinational logic functions • Sequential logic functions • Addressing • Timers & counters • Clock generators • Monostable and bistable circuits • Algebra operation: addition, subtraction, multiplication,division • BCD/binary and Binary/BCD conversions • Integrated functions of fast counting, frequencymeasurement, positioning • Program Blocs • PID control with auto-tuning • Interrupt related to internal and external events • Programming and use of industrial operators panels • Industrial networks: ProfiNet Typical application • Mechatronics modules PID regulations • Process control (Level, flow, pressure, temperature) PLC and PC Communication • Inputs/Outputs diagnosis • Internal states diagnosis • I/O and internal variables forcing • PLC networks (Master/Slave) TECHNICAL SPECIFICATIONS: • Tabletop metal box with press-formed aluminium sectionstructure • Side handles, not protruding, for easy transport in thelaboratory • Front panel, in insulating material, with silk screenrepresentation of the diagrams and inner components of theequipment • 24 Vdc/2 A power supply for control of the digital inputs andoutputs. With electronic protection against short-circuits andoverloads. • 24 Vac/2 A power supply relay outputs control with fuseprotection against overloads • 1 3 and 1/2-digit digital voltmeter for measurement of thevoltage present across the inputs or the analog output 0.1Vdc resolution. • 1 Rotating switch for voltmeter input selection • 2 analog inputs V/I: 0÷10 Vdc, 0÷20 mA • 1 analog output V/I: ±10 Vdc, 0÷20 mA • 14 Digital standard inputs of which 6 special for fast counting • Digital inputs simulator with permanent and pulse stateswitches • 10 24 Vdc digital outputs of which 2 with f=100 kHz pulses • Safety terminals, standard ø 4 mm and ø 2 mm for connectionof the inputs and outputs to external devices.
Digital outputs interfacing • With 10 Aac/2 Adc relay • Transistor for fast applications PLC characteristics • Power Supply: 24 Vdc • Hardware clock: YES • Backup time: 240 h • Working record: 50 kbyte • Data record: 2 Mbyte • Speed: 0,1 µs for binary instruction • Programming interface: TCP/IP • Network interface: PROFINET • Digital inputs: 14 at 24 Vdc; potential separation; protectionfrom polarity inversion. Bit, byte, word addressing, fromwhich 6 with fast counting functions • Input state display: YES (green LED) • Digital outputs: 10 at 24 Vdc/0,5A; galvanic separationfrom CPU; immunity against short-circuits. Bit, byte, wordaddressing from which 2 with f = 100 kHz pulses • Output state display: YES (LED diodes) • Analog inputs: 2 voltage/current • Range of the analog input voltage: 0..10 Vdc • Range of the analog input current: 0÷20 mA • Analog outputs: 1 voltage\current • Range of the analog output voltage: ±10 Vdc • Range of the analog output current: 0..20 mA • Ethernet cable for connection to PC included • Single-phase power supply cable Power supply: 230 Vac 50 Hz single-phase(Other voltage and frequency on request) Dimensions: 415 x 400 x 150 mm Net Weight: 10 kg